Podklad vinuta.eu
SlovenskoNemeckoVeµká BritániaTaliansko
 

Main Menu

ISO 9001:2001

Certifikát kvality ISO 9001:2001

Who is On-line

Aktuell 3 Gäste online
PDF Drucken E-Mail

Sealed transformers for halogen lights


 
Properties:


Single phase transformers sealed in plastic housing for current supply or halogen lamps
Constructed according to EN 61558-2-6
Supply voltage 230V/50-60Hz
Output voltage 11,5V
Separate winding
Protection from the primary side by the return thermal fuse 120°C and by the glass fuse T 5x20
Class of protection II
Thermal insulation class T 40/B
Test voltage 4kV
Protection IP 20
 



        Power
VA
     
Secondary current
A
Size of transformer Dimensions for installation (mm) Weight
kg
a b c d e f
60 5,2 EI 75/32,7 90 52,5 100 66,2 63,8 d4,2 1,3
100 8,7 EI 96/32 115 70 129,5 84,7 74,6 d6,2 2,9
150 13,0 EI 96/45,8 115 70 129,5 84,7 84,4 d6,2 3,6
200 17,4 EI 96/59,8 115 70 129,5 84,7 99 d6,2 4,4
300 26,1 EI 120/53,8 150,5 85 176,8 106,7 108,8 d8,5 6,1
400 34,8 EI 120/70 150,5 85 176,5 106,8 129 d8,5 7,6
500 43,5 EI 120/73,8 150,5 85 176,5 106,8 129 d8,5 8,0
 
© 2012 vinuta.eu/de
Joomla!
web site hit counter